Understanding Industrial Filtration

A Guide to Media Types

  • 17 September 2019
  • Author: Chem-Aqua, Inc
  • Number of views: 54
  • 0 Comments
Understanding Industrial Filtration

Waters from all over the world may contain suspended solids, microorganisms, and other unwanted contaminants that can cause damage to water systems. Heat exchangers, boiler tubes, cooling tower fill, system piping, etc. can become fouled without proper filtration. This results in a reduction in energy efficiency and increased maintenance repair costs.

Water Treatment Challenges in Thermal Storage Systems

Water Treatment Challenges in Thermal Storage Systems

Thermal energy storage (TES) systems are cooling systems that can use ice banks, brine systems, or chilled water storage tanks to capture BTUs for the purpose of removing a heat load at another point in time. In practice, the chillers for the TES operate outside peak electrical load hours and store the BTUs in the preferred form for use during peak electrical load hours. This practice reduces strain on the electrical grid and provides both cost and energy savings for the owner.

Guidelines for Inspecting a Boiler

  • 27 August 2019
  • Author: Chem-Aqua, Inc
  • Number of views: 337
  • 0 Comments
Guidelines for Inspecting a Boiler

The purpose of a boiler inspection is to provide assurance of equipment integrity to minimize safety issues with operating a pressure vessel. A minimal frequency is established by law and the Insurance Company that is covering customer liability in case of any operational failures. It has a useful secondary function of acting as an early warning of potential problems and determine the water treatment program’s effectiveness.

An internal boiler waterside inspection consists of all waterside areas of the vessel (e.g., steam and water areas, blowdown lines, feedwater connections, and low water safety devises) as well as dearators, superheaters, economizers, and blowdown heat exchangers. If possible, this inspection...

Understanding Cooling System Control Ranges and Critical Parameters

  • 13 August 2019
  • Author: Chem-Aqua, Inc
  • Number of views: 520
  • 0 Comments
Understanding Cooling System Control Ranges and Critical Parameters

Cooling towers are a critical component in many water systems, providing comfort or process cooling across a broad spectrum of technologies and applications. Cooling towers vary greatly in design and footprint, but all have the main goal: to provide removal of waste heat from processes or building systems. Control parameters are critical to maintaining any cooling system to improve water and energy efficiency, maximize equipment life expectancy, reduce hazards, and minimize downtime.

How Microbiological Filters Work

Understanding the Basics of Microfiltration

How Microbiological Filters Work

Hospitals and healthcare facilities are becoming more aware of the dangers of waterborne pathogens that can exist in their manmade plumbing systems. With growing concern of preventing infections, point-of-use (POU) filtration has been more frequently used in the healthcare market to aid in reducing bacteria counts found in water. However, not all filters are created equally, and it is important to understand the basics of microbiological filtration.

RSS
12345678910Last