Water Treatment for Evaporative Condensers

Important Differences You Need To Know

  • 11 May 2021
  • Author: Tim Daniels
  • Number of views: 755
  • 0 Comments
Water Treatment for Evaporative Condensers

Evaporative condensers are commonly used for heat rejection in low temperature ammonia refrigeration applications in cold storage and food processing plants. Although often confused with standard cooling towers, there are some key differences between evaporative condensers and the cooling tower systems used in HVAC applications. Understanding these differences and the challenges they present is important for water treatment program success.

The Fundamentals of Heat Transfer

The Fundamentals of Heat Transfer

Transferring heat into a process or rejecting excess heat from your facility is critical to keeping your facility up and running. Failure to transfer heat effectively to and from your equipment and processes may lead to increased operating costs, downtime, unscheduled maintenance, and reduced equipment life. Heat always flows from higher temperature to lower temperature in one of three ways: conduction, convection, and radiation.

Using Steam Accumulators to Satisfy Fluctuating Boiler Steam Demand

  • 1 December 2020
  • Author: Jeff Lazor
  • Number of views: 1792
  • 0 Comments
Using Steam Accumulators to Satisfy Fluctuating Boiler Steam Demand

Modern boiler plants are increasingly focused on energy efficiency, reducing their physical footprint, as well as minimizing capital and installation costs. Companies are striving to keep their total cost of operation as low as possible to remain competitive in the global economy. One of the challenges is having a steam supply that can handle large variations in demand. If the boiler is too small to handle peak demands, the plant cannot operate as designed. If the boiler is sized to handle short bursts of steam, the boiler may be oversized and have higher energy input versus output due to lower efficiencies at lower loads.

Importance of Biofilm Monitoring

What Standard Microbiological Tests Don’t Show

  • 17 November 2020
  • Author: John Bychkowski
  • Number of views: 1524
  • 0 Comments
Importance of Biofilm Monitoring

Uncontrolled microbiological growth in cooling and process water systems is a multi-billion dollar problem for businesses each year. The primary cause of this expensive problem is biofilm. Biofilms form when bacteria and other microorganisms found in the bulk water attach to exposed surfaces and begin to produce a mass of biopolymers known as extracellular polymeric substance (EPS). The EPS provides a sticky, protective barrier that allows complex communities of bacteria to thrive and exponentially grow. Bulky, biofouling deposits can quickly form as the EPS traps dirt, corrosion byproducts, and other debris suspended in the water, leading to blockages.

The Future of Industrial Water Treatment

One Water Treater’s Perspective

  • 10 November 2020
  • Author: Tyler Anderson
  • Number of views: 1191
  • 0 Comments
The Future of Industrial Water Treatment

Covid-19 has rapidly altered the daily life of Americans in a way that few other events have and industrial water treatment professionals are no exception. Field service representatives have had to deal with new access restrictions at customer sites, corporate engineering staff are working from home and learning how to remotely diagnose problems and support field staff, supply chains have been strained, and shipping has dealt with massive increases in volume. All of these challenges have caused companies to take a step back and look introspectively at their business model and see what changes they can make to become more nimble and efficient. What does this mean for the future of industrial water treatment?

RSS